Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: Sub Graphtec WR7700 Chan. Tests (1 year) CAL VER /5500 DATE: 22-Sep-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.1 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 11 NUMBER OF LINES: 153 CONFIGURATION: Fluke 5500A ============================================================================= # # Compatibility: # 5500/CAL 5.0 or MET/CAL 5.0 or later # # Subprocedures: # None # # Required Files: # None # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5500A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 DISP {Procedure not formally tested with UUT.} 1.001 DISP {See procedure README file.} 1.002 ASK- P F V 1.003 ASK+ K X 1.004 RSLT =[MEM2] 1.005 HEAD [MEM2]: {AMPLIFIER} 1.006 DISP Connect the 5500A NORMAL HI and LO to the [MEM2] input. 1.006 DISP 1.006 DISP Press the MODE key to set the DISPLAY mode. 1.007 SET RANGE : 0.1 V 1.007 SET MEAS. : DC 1.007 SET FILT. : 5 Hz 1.008 HEAD [MEM2] AMPLIFIER: {.1V Range} 1.009 5500 0V S 2W 1.010 DISP Turn the POSITION knob and adjust the display for 0.0. 1.011 5500 50mV S 2W 1.012 EVAL -s "50.0% +/- 1.6%" : Does [MEM2] indicate 50.0% +/- 1.6%? 2.001 HEAD [MEM2] AMPLIFIER: {1V Range} 2.002 SET RANGE : 1 V 2.003 5500 0.5V S 2W 2.004 EVAL -s "50.0% +/- 1.6%" : Does [MEM2] indicate 50.0% +/- 1.6%? 3.001 5500 0.9V S 2W 3.002 EVAL -s "90.0% +/- 1.6%" : Does [MEM2] indicate 90.0% +/- 1.6%? 4.001 HEAD [MEM2] AMPLIFIER: {10 V Range} 4.002 DISP Set the RANGE to 10 V. 4.003 5500 5.0V S 2W 4.004 EVAL -s "50.0% +/- 1.6%" : Does [MEM2] indicate 50.0% +/- 1.6%? 5.001 5500 9.0V S 2W 5.002 EVAL -s "90.0% +/- 1.6%" : Does [MEM2] indicate 90.0% +/- 1.6%? 6.001 HEAD [MEM2]: {AMPLIFIER AMPLITUDE} 6.002 SET RANGE : 0.1V 6.002 SET MEAS. : GND 6.002 SET FILT. : 5Hz 6.003 DISP Press the MODE key to select the DIR Y-T mode. 6.003 DISP 6.003 DISP Press the PLOT key (F1) to recall the PLOT menu, and 6.004 SET GRID : 10mm fine 6.004 SET CHART SPEED : 10mm/s 6.005 DISP Press the START/STOP key to feed the paper. 6.006 MESS Turn the POSITION knob and verify that the recorded line 6.006 MESS deflects full scale. In doing this, verify that the 6.006 MESS POSITION LED changes continuously. 6.007 EVAL -s "Full Scale Deflection" : Does [MEM2] deflect full scale? 7.001 MATH S[1] = "LED changes continuously" 7.002 EVAL -s S[1] : Does Position LED change continuously? 8.001 MESS 8.002 DISP Adjust the [MEM2] POSITION knob to center scale. 8.003 SET RANGE : 0.1 V 8.003 SET MEAS. : DC 8.003 SET FILT. : 5 Hz 8.004 5500 0.06V S 2W 8.005 PORT [D1500] 8.006 5500 -0.06V S 2W 8.007 PORT [D1500] 8.008 MESS Measure the distance from the grid to the limiter 8.008 MESS (where the recorded line "pegs"). 8.008 MESS 8.009 MATH S[1] = "Grid to limiter distance is 1.2mm +/-0.5mm." 8.010 EVAL S[1] : Is distance between grid & limiter 1.2mm +/-0.5mm? 9.001 MESS 9.002 DISP Press the START/STOP key to stop the paper feed. 9.003 HEAD [MEM2]: {MEMORY DATA AND TRIGGER CHECKS} 9.004 DISP Press the MODE key to select the MEM Y-T mode. 9.004 DISP 9.004 DISP Press the PLOT function key (F1) to recall the menu. 9.005 SET Format : 20mm x 8 9.005 SET Grid : 10div coarse 9.005 SET Paper Format : Std 9.005 SET Scaling Factor : 1 9.005 SET List : No 9.005 SET Scale : Yes 9.006 DISP Press the PREV. key to return to the initial screen. 9.006 DISP 9.006 DISP Press the MEMO function key (F3) to recall the menu. 9.007 SET Samp. intv. : 8u 9.007 SET Memory bank : 16k 9.007 SET Memory size : 12.5% 9.007 SET Printout area : 0% thru 100% 9.008 DISP Press the PREV. key to return to the initial screen. 9.008 DISP 9.008 DISP Press the TRIG function key (F2) to recall the menu. 9.009 SET Mode : A 9.009 SET Trig. delay : +000% 9.009 SET Trig. action : Single 9.009 SET RANGE : 0.5 V 9.009 SET MEAS. : DC 9.009 SET FILT. : OFF 9.009 SET POSITION : 50% 9.010 DISP [MEM2] : 75% Pos Slope 9.011 DISP Note: DO NOT FEED THE CHART PAPER. 9.012 5500 0.25Vp 1kH SI S 2W 9.013 DISP Press the START/STOP key to record data. 9.013 DISP 9.013 DISP Allow signal to be recorded before continuing. 9.014 5500 * S 9.015 DISP Press the PRINT key to output data. 9.015 DISP 9.015 DISP Verify that the waveform (at the trigger point) 9.015 DISP rises from the 75% point. 9.016 EVAL Does {waveform rise from the 75% point}? 10.001 HEAD [MEM2]: {NOISE} 10.002 DISP Disconnect the 5500A from [MEM2] 1 and short the 10.002 DISP [MEM2] (+) and (-) input terminals. 10.002 DISP 10.003 DISP Press the MODE key to select the DIR Y-T mode. 10.003 DISP 10.003 DISP Shift the POSITION of [MEM2] 10%. 10.004 SET RANGE : 10 V 10.004 SET FIL. : OFF 10.004 SET MEAS. : DC 10.005 DISP Set the FORMAT in the PLOT menu to 160mm x 1. 10.006 DISP Press the START/STOP key to start recording.[D2000] 10.007 DISP Press the START/STOP key to stop recording.[D2000] 10.008 MESS Measure the width of the recorded line. 10.008 MESS 10.009 EVAL -s "Width is within 1.5mm." : Is width within 1.5mm.? 11.001 MESS 11.002 END